Official distributor in Russia and CIS countries
HII pumps model selection chart
HII pumps, spares and seal kits availability from stock in Moscow
HII air driven liquid pumps catalog
Parameter | Value |
---|---|
Outlet pressure | 80 - 838 bar / 8.0 - 83.8 MPa - operating range |
Drive type | pneumatic / hand (modification H/HS), single air drive section |
Pump section type | single plunger |
Area ratio | 81 |
Volume displacement per cycle | 1.3 ml/cycle |
Flow rate / Test piece prefill speed |
up to 0.9 l/min - maximum value 0 - 0.13 l/min - operating range |
Pressure build speed in a prefilled test piece | up to 212 bar×l/s - maximum value 0 - 31 bar×l/s - operating range |
Air drive pressure | 10.3 bar - maximum value 5 - 10 bar - recommended range 2 bar - minimum required value |
Inlet pressure | up to 700 bar - maximum value 4 - 10 bar - recommended range 2 bar - minimum recommended value |
Air Drive Temperature limitations | up to + 65 °С - maximum value -3°С ... +3°С - recommended dew point -12 °С - minimum value |
Hydraulic body | 316 SS |
Hydraulic plunger | 316 SS |
Inlet check valve | 316 SS |
Outlet check valve | 316 SS |
Static O-rings | BUNA-N - basic model; Viton - modifications |
Plunger seal | UHMWPE |
Inlet liquid port | 3/8" NPT |
Outlet liquid port | 1/4" NPT |
Air drive port | 1/4" NPT |
Please specify the modification when ordering the pump for the pumped liquid and operating conditions.
Analog | Main features |
---|---|
Haskel MS-71; M-71; MCPV-71; 29723-71 | Area ratio: 82 Volume displacement per cycle: 1.0 ml/cycle Outlet pressure max: 607 bar Inlet liquid port 3/8" NPT Outlet liquid port: 1/4" NPT Air drive port: 1/4" NPT Haskel liquid pumps catalog |
HYDR-STAR AHP03-1S-71 | Area ratio: 82 Volume displacement per cycle: 1.0 ml/cycle Outlet pressure max: 607 bar Inlet liquid port: 3/8" NPT Outlet liquid port: 1/4" NPT Air drive port: 1/4" NPT HYDRSTAR liquid pumps catalog |
MAXIMATOR MO72; M72; M72L; M72LVE; MSF72; MSF72L | Area ratio: 86 Volume displacement per cycle: 1.5 ml/cycle Outlet pressure max: 860 bar Inlet liquid port: 3/8" BSP Outlet liquid port: 3/8" BSP (MO72 - 1/4"BSP) Air drive port: 3/8" BSP MAXIMATOR liquid pumps size M72 |
MAXIMATOR MO72D; M72D; M72DVE | Area ratio: 86,0 Volume displacement per cycle: 3,8 ml/cycle Outlet pressure max: 860 бар Inlet liquid port: 2 x 3/8" BSP Outlet liquid port: 2 x 3/8" BSP (MO22D - 2 x 1/4"BSP) Air drive port: 3/8" BSP MAXIMATOR liquid pumps size M72D |
RESATO P80-65-1/U/N | Area ratio: 65 Volume displacement per cycle: 1.57 ml/cycle Outlet pressure max: 455 bar Inlet liquid port: 3/8" BSP Outlet liquid port: M16x1.5" Air drive port: not available Resato pumps type P80 |