Official distributor in Russia and CIS countries
Model range of mobile units for hydraulic testing KGF-TEST M1 series
Mobile hydraulic installation KGS-TEST-M1-1800-230- L designed for hydraulic testing of high-pressure valves, needle valves, manifolds, shut-off valves and valve assemblies in the range of 700-1800 bar.
| Pump Model | 5L-SD-230 |
| Number of pumps in the unit | 1 |
| Drive Type | pneumatic |
| Type of hydraulic part | single plunger |
| Type of pneumatic part | two-piston |
| Multiplication factor | 230 |
| Range of discharge operating pressures | 230 - 2379 bar |
| Maximum allowable pressure in the pneumatic network | 10.3 bar |
| Recommended pressure in the pneumatic network | 5 - 8 bar |
| Minimum pressure in the pneumatic network | 2 bar |
| Feed per cycle | 7.9 ml/cycle |
| Efficiency | 0 - 0.47 (1.7) l/min |
| Maximum permissible fluid pressure at the inlet fitting of the installation | 7 bar |
| Recommended fluid pressure at the inlet fitting of the installation | 3 bar |
| Minimum fluid pressure at the inlet fitting of the installation | 1 bar |
| Operating temperature range of the pneumatic actuator | -12 °C ... +65 °C |
| Operating temperature range of the hydraulic part | +3 °C ... +40 °C |