Official distributor in Russia and CIS countries
HII pumps model selection chart
HII air driven liquid pumps catalog
| Parameter | Value |
|---|---|
| Outlet pressure | 120 -1189 bar / 12.0 - 118.9 MPa - operating range |
| Drive type | pneumatic, single air drive section |
| Pump section type | single plunger |
| Area ratio | 115 |
| Volume displacement per cycle | 7.9 ml/cycle |
| Flow rate / Test piece prefill speed |
up to 2.1 l/min - maximum value 0 - 0.5 l/min - operating range |
| Pressure build speed in a prefilled test piece | up to 500 bar×l/s - maximum value 0 - 113 bar×l/s - operating range |
| Air drive pressure | 10.3 bar - maximum value 5 - 10 bar - recommended range 1 bar - minimum required value |
| Inlet pressure | up to 1189 bar - maximum value 10 - 100 bar - recommended range 2 bar - minimum recommended range free flow / moderate vacuum / self-prime - minimum value |
| Air Drive Temperature limitations | up to + 65 °С - maximum value -3°С ... +3°С - recommended dew point -12 °С - minimum value |
| Hydraulic body | 15-5 PH |
| Hydraulic plunger | 15-5 PH |
| Inlet check valve | 15-5 PH |
| Outlet check valve | 15-5 PH |
| Static O-rings | BUNA-N - basic model; Viton - modifications |
| Plunger seal | UHMWPE |
| Inlet liquid port | 1/2" NPT |
| Outlet liquid port | 1/2" NPT |
| Air drive port | SAE 3/4"-16 |
Please specify the modification when ordering the pump for the pumped liquid and operating conditions.