Official distributor in Russia and CIS countries
Model range of mobile units for hydraulic testing KGF-TEST M1 series
Portable hydraulic installation KGS-TEST-M1-1200-125- S based on the HII 3L-SS-125 pump is designed for crimping pipelines, ultra-high pressure lines, gas pipelines in the pressure range of 400-1000 bar in constant mode, up to 1200 bar in short-term operation.
Pump Model | 3L-SS-125 |
Number of pumps in the unit | 1 |
Drive Type | low-power pneumatic |
Type of hydraulic part | single plunger |
Type of pneumatic part | single piston |
Multiplication factor | 125 |
Range of discharge operating pressures | 250-1034 bar briefly up to 1200 bar |
Maximum allowable pressure in the pneumatic network | 10.3 bar |
Recommended pressure in the pneumatic network | 5-10 bar |
Minimum pressure in the pneumatic network | 2 bar |
Feed per cycle | 0.8 ml/cycle |
Efficiency | 0 - 0.08 (0.5) l/min |
Maximum permissible fluid pressure at the inlet fitting of the installation | 7 bar |
Recommended fluid pressure at the inlet fitting of the installation | 3 bar |
Minimum fluid pressure at the inlet fitting of the installation | 1 bar |
Operating temperature range of the pneumatic actuator | -12 °C ... +65 °C |
Operating temperature range of the hydraulic part | +3 °C ... +40 °C |