Official distributor in Russia and CIS countries
HII pumps model selection chart
HII air driven liquid pumps catalog
| Parameter | Value |
|---|---|
| Outlet pressure | 230 - 2379 bar / 23 - 237.9 MPa - operating range |
| Drive type | pneumatic, double air drive section |
| Pump section type | double acting, twin plunger |
| Area ratio | 230 |
| Volume displacement per cycle | 15.7 ml/cycle |
| Flow rate / Test piece prefill speed |
up to 3.4 l/min - maximum value 0 - 0.94 l/min - operating range |
| Pressure build speed in a prefilled test piece | up to 810 bar×l/s - maximum value 0 - 224 bar×l/s - operating range |
| Air drive pressure | 10.3 bar - maximum value 5 - 10 bar - recommended range 2 bar - minimum required value |
| Inlet pressure | 700 bar - maximum recommended value 10 - 700 bar - recommended range 2 bar - minimum recommended value |
| Air Drive Temperature limitations | up to + 65 °С - maximum value -3°С ... +3°С - recommended dew point -12 °С - minimum value |
| Hydraulic body | 15-5 PH |
| Hydraulic plunger | 15-5 PH |
| Inlet check valve | 15-5 PH |
| Outlet check valve | 15-5 PH |
| Static O-rings | BUNA-N - basic model; Viton - modifications |
| Plunger seal | UHMWPE |
| Inlet liquid port | 1/2" NPT |
| Outlet liquid port | 1/4" SP |
| Air drive port | SAE 3/4"-16 |
Please specify the modification when ordering the pump for the pumped liquid and operating conditions.