Official distributor in Russia and CIS countries
| Drive type | pneumatic: single air drive section |
| Gas section type | two stage |
| Number of gas compression stages | 2 |
| Area ratio (higher) AR | 92 |
| Air drive pressure range PAD | 0.8 ... 10 bar 12 ... 150 PSI |
| Maximum safe inlet gas pressure PIN.MAX | 1034 bar 15000 PSI |
| Inlet gas pressure range PIN Operation mode limitations |
10 ... 650 bar 150 ... 9400 PSI |
| Maximum safe outlet gas pressure POUT.MAX | 2068 bar 30000 PSI |
| Maximum achievable outlet gas pressure POUT Operation mode limitations |
Limited by POUT.MAX |
| Assist factor AF | 1.84 |
| Approximate stall point POUT=AR×PAD+AF×PIN | POUT= 92×PAD+1.84×PIN |
| Recommended gas compression ratio POUT/PIN | 6:1 to 36:1 |
| Displacement per cycle | 29 cm3 1.76 in3 |
| Maximum available gas flow | 450 l/min |
| Average available gas flow | 40 ... 200 l/min |
| Efficiency index | ★ ★ ★ ★ ☆ |
| Air drive temperature range (standard) | - 53 °С ... + 135 °С - 65 F ... + 275 F |
| Air drive temperature range (Viton) | - 40 °С ... + 232 °С - 40 F ... + 450 F |
| Gas section temperature range | - 40 °С ... + 198 °С - 40 F ... + 390 F |
| Dimensions L×W×H | 638 mm × 244 mm × 241 mm 25.1" × 9.61" × 9.5" |
| Air Drive | 8 SAE BOSS |
| Gas Inlet | 3/8” SAE or 1/4”SP | Gas Outlet | Super Pressure 1/4" |
| Remote Pilot | 4 SAE BOSS |
| Air Drive metallic parts | Aluminium - standard SS - on request |
| Air Drive seals | Buna - standard Viton - modification -V |
| Gas end metallic parts | SS - standard | Gas end seals | Viton - standard |
| Nitrogen, Argon, оther inert gases except He - standard purity | basic model |
| Pure / ultra-pure gases | on request |
| Helium (He) | H2 modification |
| Hydrogen (H2) | -P-P1-H2 modification |
| Сarbon dioxide (CO2) | -CO2 modification |
| Dangerous, flammable gases | -P-P1 modification / on request |