Official distributor in Russia and CIS countries
| Drive type | pneumatic: single air drive section |
| Gas section type | double acting |
| Number of gas compression stages | 1 |
| Area ratio AR | 29 |
| Air drive pressure range PAD | 0.8 ... 10 bar 12 ... 150 PSI |
| Inlet gas pressure range PIN | 28 ... 414 bar 400 ... 6000 PSI |
| Maximum safe outlet gas pressure POUT.MAX | 414 bar 6000 PSI |
| Assist factor AF | 1 |
| Approximate stall point POUT=AR×PAD+AF×PIN | POUT= 29×PAD+PIN |
| Recommended gas compression ratio POUT/PIN | 1:1 to 8:1 |
| Displacement per cycle | 18.4 cm3 1.12 in3 |
| Maximum available gas flow at ideal conditions | 300 l/min |
| Average available gas flow Calculations required - please consult our experts |
30 ... 150 l/min |
| Efficiency index | ★ ★ ★ ☆ ☆ |
| Air drive temperature range (standard) | - 53 °С ... + 135 °С - 65 F ... + 275 F |
| Air drive temperature range (Viton) | - 40 °С ... + 232 °С - 40 F ... + 450 F |
| Gas section temperature range | - 40 °С ... + 198 °С - 40 F ... + 390 F |
| Dimensions L×W×H | 441 mm × 142 mm × 140 mm 17.35" × 5.6" × 5.5" |
| Air Drive | 1/4” NPT |
| Gas Inlet | SAE 1/4" | Gas Outlet | SAE 1/4" |
| Exhaust | 1/4” NPT |
| Remote Pilot | 1/8” NPT |
| Air Drive metallic parts | Aluminium - standard SS - not available |
| Air Drive seals | Buna - standard Viton - modification -V |
| Gas end metallic parts | SS - standard | Gas end seals | Viton - standard |
| Air, Nitrogen, Argon, оther inert gases except He - standard purity | basic model |
| Pure / ultra-pure gases | O2 modification / on request |
| Oxygen O2 | O2 modification |
| Helium (He) | H2 modification |
| Hydrogen (H2) | -P-H2 modification |
| Сarbon dioxide (CO2) | -CO2 modification |
| Dangerous, flammable gases | -P modification / on request |