Official distributor in Russia and CIS countries
HII pumps model selection chart
HII air driven liquid pumps catalog
Parameter | Value |
---|---|
Outlet pressure | 450 - 4654 bar / 45.0 - 465.4 MPa - operating range |
Drive type | pneumatic, single air drive section |
Pump section type | single plunger |
Area ratio | 450 |
Volume displacement per cycle | 1.9 ml/cycle |
Flow rate / Test piece prefill speed |
up to 0.52 l/min - maximum value 0 - 0.1 l/min - operating range |
Pressure build speed in a prefilled test piece | up to 124 bar×l/s - maximum value 0 - 27 bar×l/s - operating range |
Air drive pressure | 10.3 bar - maximum value 5 - 10 bar - recommended range 1 bar - minimum required value |
Inlet pressure | up to 700 bar - maximum value 100 - 700 bar - recommended range 100 bar - minimum recommended range |
Air Drive Temperature limitations | up to + 65 °С - maximum value -3°С ... +3°С - recommended dew point -12 °С - minimum value |
Hydraulic body | 15-5 PH |
Hydraulic plunger | STELLITE |
Inlet check valve | 15-5 PH |
Outlet check valve | 15-5 PH |
Static O-rings | BUNA-N - basic model; Viton - modifications |
Plunger seal | UHMWPE |
Inlet liquid port | 1/2" NPT |
Outlet liquid port | 1/4" SP |
Air drive port | SAE 3/4"-16 |
Please specify the modification when ordering the pump for the pumped liquid and operating conditions.