Drive type | pneumatic: single air drive section |
Gas section type | two stage |
Number of gas compression stages | 2 |
Area ratio (higher) AR | 92 |
Air drive pressure range PAD | 0.8 ... 10 bar 12 ... 150 PSI |
Maximum safe inlet gas pressure PIN.MAX | 620 bar 9000 PSI |
Inlet gas pressure range PIN Operation mode limitations |
7 ... 150 bar 100 ... 2175 PSI |
Maximum safe outlet gas pressure POUT.MAX | 2068 bar 30000 PSI |
Maximum achievable outlet gas pressure POUT Operation mode limitations |
1380 bar 20000 PSI |
Assist factor AF | 3.06 |
Approximate stall point POUT=AR×PAD+AF×PIN | POUT= 92×PAD+3.06×PIN |
Recommended gas compression ratio POUT/PIN | 6:1 to 36:1 |
Displacement per cycle | 51 cm3 3.1 in3 |
Maximum available gas flow | 400 l/min |
Average available gas flow | 40 ... 200 l/min |
Efficiency index | ★ ★ ★ ★ ☆ |
Air drive temperature range (standard) | - 53 °С ... + 135 °С - 65 F ... + 275 F |
Air drive temperature range (Viton) | - 40 °С ... + 232 °С - 40 F ... + 450 F |
Gas section temperature range | - 40 °С ... + 198 °С - 40 F ... + 390 F |
Dimensions L×W×H | 638 mm × 244 mm × 241 mm 25.1" × 9.61" × 9.5" |
Air Drive | 8 SAE BOSS |
Gas Inlet | 3/8” SAE or 1/4”SP | Gas Outlet | Super Pressure 1/4" |
Remote Pilot | 4 SAE BOSS |
Air Drive metallic parts | Aluminium - standard SS - on request |
Air Drive seals | Buna - standard Viton - modification -V |
Gas end metallic parts | SS - standard | Gas end seals | Viton - standard |
Nitrogen, Argon, оther inert gases except He - standard purity | basic model |
Pure / ultra-pure gases | on request |
Helium (He) | H2 modification |
Hydrogen (H2) | -P-P1-H2 modification |
Сarbon dioxide (CO2) | -CO2 modification |
Dangerous, flammable gases | -P-P1 modification / on request |