Drive type | pneumatic: double air drive section |
Gas section type: | single acting |
Number of gas compression stages | 1 |
Area ratio AR | 60 |
Air drive pressure range PAD | 0.8 ... 10 bar 12 ... 150 PSI |
Maximum safe inlet gas pressure PIN.MAX | 620 bar 9000 PSI |
Inlet gas pressure range PIN Operation mode limitations |
27 ... 600 bar 300 ... 8700 PSI |
Maximum safe outlet gas pressure POUT.MAX | 620 bar 9000 PSI |
Maximum achievable outlet gas pressure POUT Operation mode limitations |
600 bar 8700 PSI |
Assist factor AF | 0 |
Approximate stall point POUT=AR×PAD+AF×PIN | POUT= 60×PAD |
Recommended gas compression ratio POUT/PIN | 1:1 to 8:1 |
Displacement per cycle | 51 cm3 3.1 in3 |
Maximum available gas flow at ideal conditions | 500 l/min |
Average available gas flow Calculations required - please consult our experts |
50 ... 300 l/min |
Efficiency index | ★ ★ ★ ☆ ☆ |
Air drive temperature range (standard) | - 53 °С ... + 135 °С - 65 F ... + 275 F |
Air drive temperature range (Viton) | - 40 °С ... + 232 °С - 40 F ... + 450 F |
Gas section temperature range | - 40 °С ... + 198 °С - 40 F ... + 390 F |
Dimensions L×W×H | 580 mm × 217 mm × 241 mm 22.83" × 8.56" × 9.5" |
Air Drive | 8 SAE BOSS |
Gas Inlet | 3/8” SAE / 1/4” SP combined port |
Gas Outlet | 3/8” SAE / 1/4” SP combined port |
Remote Pilot | 4 SAE BOSS |
Air Drive metallic parts | Aluminium - standard SS - on request |
Air Drive seals | Buna - standard Viton - modification -V |
Gas end metallic parts | SS - standard | Gas end seals | Viton - standard |
Air, Nitrogen, Argon, оther inert gases except He - standard purity | basic model |
Pure / ultra-pure gases | O2 modification / on request |
Oxygen O2 | O2 modification |
Helium (He) | H2 modification |
Hydrogen (H2) | -P-H2 modification |
Сarbon dioxide (CO2) | -CO2 modification |
Dangerous, flammable gases | -P modification / on request |